Search results for "Flow injection analysis"

showing 10 items of 73 documents

Creatinine determination in urine samples by batchwise kinetic procedure and flow injection analysis using the Jaffé reaction: chemometric study

2001

The classical Jaffé reaction for the determination of creatinine in urine samples is tested. A comparative study of the main analytical characteristics focussed to minimize the bias error and improve the precision, for the batchwise and flow injection (FI) methods is realized. Also, the effect of the albumin concentration in the determination of creatinine has been studied. Different analytical signals were studied. Absorbance increments at different times permit to estimate the creatinine concentration free from bias error in urine by the batchwise method using the calibration graph obtained with creatinine standards and no measurement of the blank solution is needed. The lineal interval w…

AbsorbanceFlow injection analysisCreatininechemistry.chemical_compoundChromatographychemistryCalibration curveStandard additionCalibrationAnalytical chemistryUrineQuantitative analysis (chemistry)Analytical ChemistryTalanta
researchProduct

Determination of nitrite by inhibition of the chemiluminescence of acriflavine in a flow-injection assembly

2001

The indirect determination of nitrite was performed with a flow-injection assembly on the basis of the inhibition of the analytical output obtained in a luminometer by oxidation of acriflavine. The acriflavine solution merged with the nitrite and the resulting mixture was injected into a pure water stream. This solution merged with the oxidant solution (potassium permanganate in sulfuric acid medium) and the resulting chemiluminiscence was affected (inhibited) by the presence of nitrite after reaction with the aminoacridine. The method was applicable over the range 10–800 μg l−1 of nitrite with a correlation coefficient of 0.9960. The relative standard deviation was 1.4% and the throughput …

AminoacridineChromatographyInorganic chemistrySulfuric acidAmberliteBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganatechemistrylawFlow Injection AnalysisLuminescent MeasurementsElectrochemistryEnvironmental ChemistryAcriflavineEnvironmental PollutantsAcriflavineNitriteQuantitative analysis (chemistry)NitritesSpectroscopyChemiluminescenceThe Analyst
researchProduct

Spectrophotometric determination of promazine with an oxidative column in FIA manifolds

1992

Abstract A simple flow-injection spectrophotometric method for the determination of promazine is described. The two proposed procedures are based on the oxidation of analyte with a manganese dioxide column. Concentrations of promazine in the ranges 2–20 and 1–6 are determined with a relative standard deviation of 1.0%. The injection rates are 62 and 80 samples h −1 , respectively. The influence of foreign species and the determination of promazine in a pharmaceutical formulation are also reported.

AnalyteChemistry PharmaceuticalClinical BiochemistryRelative standard deviationPharmaceutical Sciencechemistry.chemical_elementManganesePharmaceutical formulationRedoxDosage formAnalytical ChemistryDrug DiscoverymedicinePromazineSpectroscopyPromazineFlow injection analysisManganeseChromatographyChemistryOxidesHydrogen-Ion ConcentrationManganese CompoundsCalibrationFlow Injection AnalysisSpectrophotometry UltravioletOxidation-Reductionmedicine.drugJournal of Pharmaceutical and Biomedical Analysis
researchProduct

Determination of the herbicide benfuresate by its photo-induced chemiluminescence using flow multicommutation methodology.

2007

The present paper deals with an analytical strategy based on coupling photo-induced chemiluminescence in a multicommutation continuous-flow methodology for the determination of the herbicide benfuresate. The solenoid valve inserted as small segments of the analyte solution was sequentially alternated with segments of the NaOH solution for adjusting the medium for the photodegradation. Both flow rates (sample and medium) were adjusted to required time for photodegradation, 90 s; and then, the resulting solution was also sequentially inserted as segments alternated with segments of the oxidizing solution system, hexacyanoferrate (III) in alkaline medium. The calibration range from 1 microg L(…

AnalyteCorrelation coefficientAnalytical chemistryFresh WaterAlkaliesAnalytical Chemistrylaw.inventionlawOxidizing agentWater Pollution ChemicalHumansPhotodegradationChemiluminescenceBenzofuransDetection limitReproducibilityChromatographyPhotolysisMolecular StructureChemistryHerbicidesVolumetric flow rateFlow Injection AnalysisLuminescent MeasurementsMineral WatersSulfonic AcidsAcidsTalanta
researchProduct

Optimization of selenium determination in human milk and whole blood by flow injection hydride atomic absorption spectrometry.

1998

abstract A flow injection hydride atomic absorption spectrometry (FI-HAAS) method was developed for determining selenium in human milk and whole blood after microwave digestion of the sample. The sample (2 mL human milk or 0.25 mL blood) was introduced into the microwave vessel with 1.5 mL HN03 and 0.25 mL H202 and 300 W (4 min) and 600 W (4 min) were applied. The digestion was completed by heating to 140 C (2-3 h). Se (VI) was reduced to Se (IV) with hydrochloric acid. The instrumental conditions for FI-HAAS (concentrations of reducing agent and carrier acid, flow rate of argon carrier gas, and sample volume injected) were optimized. The detection limit of the proposed method was 0.23 ng/m…

Analytical chemistrychemistry.chemical_elementHydrochloric acidAnalytical Chemistrylaw.inventionchemistry.chemical_compoundSeleniumlawPregnancyEnvironmental ChemistryHumansMicrowave digestionWhole bloodPharmacologyDetection limitFlow injection analysisChromatographyMilk HumanSpectrophotometry AtomicchemistryFlow Injection AnalysisFemaleIndicators and ReagentsAtomic absorption spectroscopyAgronomy and Crop ScienceQuantitative analysis (chemistry)SeleniumFood ScienceJournal of AOAC International
researchProduct

Multicommutation as a powerful new analytical tool

2002

This review presents the state of the art of the emerging continuous-flow methodology based on solenoid valves. This uses flow networks to deliver sample and reagent solutions by controlling the time of flow through the ON/OFF modes of solenoid valves and takes advantage of existing flow injection analysis (FIA) or sequential injection analysis (SIA) device or manifold configurations. It allows one to insert a single plug of sample (or reagent) into the carrier or carrier-reagent stream, mimicking the approaches of FIA or SIA. In addition to the modes used in FIA and SIA, the methodology provides a different mode, based on delivery of a series of alternating sequential insertions of very sm…

Chemical processFlow injection analysisComputer sciencebusiness.industrySolenoidSample (graphics)Analytical Chemistrylaw.inventionFlow (mathematics)lawReagentState (computer science)Process engineeringbusinessManifold (fluid mechanics)SpectroscopyTrAC Trends in Analytical Chemistry
researchProduct

FI-chemiluminometric study of thiazides by on-line photochemical reaction

2004

The present manuscript deals with a simple and sensitive flow-injection method for the chemiluminescent determination of thiazides. The method is based on the on-line photodegradation and chemiluminescent determination of the resulting photo-fragments. The on-line photodegradation is performed in basic medium by using a photoreactor consisting of a 550 cm long x 0.8 mm ID piece of PTFE tubing helically coiled around an 8 W low-pressure mercury lamp. The determination of the photo-irradiated thiazides is performed by a chemiluminescent oxidative reaction with Ce(IV) in sulphuric acid medium. A heterogeneous group of thiazides (indapamide, metolazone, hydroflumethiazide, chlorthalidone and be…

ChemiluminescencePhotochemistrymedicine.medical_treatmentClinical BiochemistryPharmaceutical SciencePhotochemistryAnalytical Chemistrylaw.inventionThiazidesFIAchemistry.chemical_compoundHydrochlorothiazidelawQUIMICA ANALITICADrug DiscoverymedicineBendroflumethiazidePhotodegradationSpectroscopyChemiluminescenceDetection limitHydroflumethiazideChromatographyThiadiazinesChemistryPhotochemical reactionHydrochlorothiazideFlow Injection AnalysisLuminescent MeasurementsPharmaceuticalsMetolazoneDiureticmedicine.drugJournal of Pharmaceutical and Biomedical Analysis
researchProduct

Three simultaneous dissolution profiles on a solid pharmaceutical formulation by a FIA manifold provided with a single spectrophotometric detector.

2003

This article deals with the simultaneous determination of three dissolution profiles in the same pharmaceutical formulation. The officially proposed procedure from the pharmacopoeias is adapted to the FIA methodology to obtain the officially recommended profile or "global profile", and two "individual" profiles, corresponding to dissolution rate of two different active principles present in the formulation; both drugs have overlapped UV-vis spectra. The simultaneous determination of several profiles is based on the derivative spectra and the zero crossing mathematical procedure for the "individual" profiles of an active principle; the "global" profile of the formulation is obtained from the…

Chemistry PharmaceuticalClinical BiochemistryPharmaceutical ScienceDerivativePharmaceutical formulationPlot (graphics)Dosage formSpectral lineAnalytical ChemistryDrug DiscoveryApplied mathematicsSpectroscopyClavulanic AcidAntibacterial agentFlow injection analysisChromatographyChemistryAmoxicillinZero crossingBromhexinePharmaceutical SolutionsPharmaceutical PreparationsSolubilityFlow Injection AnalysisSpectrophotometry UltravioletTabletsJournal of pharmaceutical and biomedical analysis
researchProduct

Simultaneous dissolution profiles of two drugs in pharmaceutical formulations by an FIA manifold

2002

Abstract This article deals with the simultaneous determination of dissolution profiles of two drugs with overlapped spectra, present in the same pharmaceutical formulation. The official procedure for the dissolution profile is adapted to the continuous-flow methodology; the dissolution vessel is connected to an FIA manifold, in which the sample aliquots from the dissolution vessel are treated in order to adjust to the suitable pH and dilution degree to be monitored. The resulting solution is injected into the carrier stream, an acetic acid–acetate buffer at pH 4.3 and forced to the flow-cell of the spectrophotometer. The simultaneous determination of both profiles is based on the first der…

ChromatographySulfamethoxazoleChemistryClinical BiochemistryPharmaceutical SciencePharmaceutical formulationTrimethoprimDosage formAnalytical Chemistrylaw.inventionDilutionAnti-Infective AgentsSolubilitylawFlow Injection AnalysisDrug DiscoveryManifold (fluid mechanics)Quantitative analysis (chemistry)DissolutionSpectroscopyAnalysis methodJournal of Pharmaceutical and Biomedical Analysis
researchProduct

In situ generation of Co(II) by use of a solid-phase reactor in an FIA assembly for the spectrophotometric determination of penicillamine

2005

[EN] A flow injection analysis (FIA) manifold for the determination of penicillamine in pharmaceutical preparations is proposed. The manifold includes a solid-phase reactor for the in situ production of the derivatizing reagent, Co(II) ion, which forms a coloured complex with penicillamine in an alkaline medium. The reactor is prepared by natural immobilization of cobalt carbonate on a polymer matrix, which endows it with a high mechanical and microbiological stability. The cobalt released by passage of a 5 x 10(-4) Mol l(-1) sulphuric acid stream at a flow-rate of 2.3 ml min(-1) is merged with a volume of 314 mu l of sample containing penicillamine in ammonium-ammonia buffer at pH 9.5 to m…

Clinical BiochemistryPharmaceutical Sciencechemistry.chemical_elementAnalytical ChemistryMatrix (chemical analysis)AbsorbanceFIAFlow injection analysisSpectrophotometryDrug DiscoveryQUIMICA ANALITICAmedicineSpectroscopyFlow injection analysisDetection limitChromatographymedicine.diagnostic_testChemistrySpectrum AnalysisPenicillaminePenicillamineReproducibility of ResultsCobaltSolid-phase reactorReagentPharmaceuticalsCobaltmedicine.drug
researchProduct